Home | Products | Thermal Desorption | JTD-505Ⅲ

JTD-505III - Auto model

JTD-505Ⅲ - Auto model

Outline
New JTD-505 III is an automated Thermal Desorption Purge & Trap Sampler that preserves the instant heating by curie point from the previous model JTD-505 II and becomes smaller body.
It performs analysis of indoor airborne molecular contamination (AMC), organic substances in and out clean room, trace emission gas of odor and outgas from electrical equipment with GC, GC/MS.
JTD-505 III works with the largest capacity of sample tube in the market called PAT (Size ID 12 mm, Length 50 mm) so that small electrical parts, polymeric materials, etc can be directly placed in without preparation steps.
VOC and outgas analysis are fully supported by PAT baking ovens to stay always clean and wide range of outgas collectors lineup.
 
Feature
Up to 15 samples can be set up on the sample rack at a time.
Programmable up to 48 samples when placing other samples on the sample rack during operation or repeat the same samples for multiple analysis.
 
<Analysis example>
1) Blank analysis between samples to check the baseline and prevent contamination.
2) Consecutive analysis with multistep temperature for a same sample.

 
  


Sensitive analysis of various samples from low to high boiling compounds.
 
Curie point heating results in sharper chromatographic peaks and high reproducibility.
 
Largest capacity quartz sample tube enables analysis of large volume collected gas sample.
 
Small electronic parts can be placed directly in the empty PAT.
 
The split can be adjusted at two locations; outlet of PAT and SAT.
 
Analytical conditions can be stored into method files to reproduce analysis.
 
Compatible to all major GC models.
 

 
   
  
 

Outline
New JTD-505 III is an automated Thermal Desorption Purge & Trap Sampler that preserves the instant heating by curie point from the previous model JTD-505 II and becomes smaller body.
It performs analysis of indoor airborne molecular contamination (AMC), organic substances in and out clean room, trace emission gas of odor and outgas from electrical equipment with GC, GC/MS.
JTD-505 III works with the largest capacity of sample tube in the market called PAT (Size ID 12 mm, Length 50 mm) so that small electrical parts, polymeric materials, etc can be directly placed in without preparation steps.
VOC and outgas analysis are fully supported by PAT baking ovens to stay always clean and wide range of outgas collectors lineup.
 
Feature
Up to 15 samples can be set up on the sample rack at a time.
Programmable up to 48 samples when placing other samples on the sample rack during operation or repeat the same samples for multiple analysis.
 
Analysis example
1) Blank analysis between samples to check the baseline and prevent contamination.
2) Consecutive analysis with multistep temperature for a same sample.

Sensitive analysis of various samples from low to high boiling compounds.
Curie point heating results in sharper chromatographic peaks and high reproducibility.
Largest capacity quartz sample tube enables analysis of large volume collected gas sample.
Small electronic parts can be placed directly in the empty PAT.
The split can be adjusted at two locations; outlet of PAT and SAT.
Analytical conditions can be stored into method files to reproduce analysis.
Compatible to all major GC models.
 

 

Specifications

Specifications

 
         JTD-505Ⅲ
       JTD-505MⅢ
Device unit 
 PAT thermal desorption 0°C to 350°C (Cooling by LN2, Heating by resistance heating) *1
 Transfer line Ambient plus 10°C to 350°C (Heating by resistance heating)
Metal capillary tube
 SAT thermal desorption Heating by curie point method (standard 280°C)
 SAT  Quartz glass packed with Tenax TA and pyrofoil 280
 SAT cooling unit minus 100°C to ambient (Cooling by LN2)
 SAT oven unit Ambient plus 10°C to 230°C (Heating by resistance heating)
 Needle Ambient plus 10°C to 300°C (Heating by resistance heating)
 GC connection Direct connection to capillary column or injector
 Dimensions/ Weight 255(W) x 210(H) x 105(D) mm / 3Kg
Loader
 PAT rack 15 tubes + 1 tube at home position
for position calibration and blank test
 Carrying mechanism Motor drive
 PAT induction air plunger Compressed air > 0.5MPa
 Dimension/weight 670(W) x 200(H) x 760(D) mm /14.3Kg   
Controller
 Touch panel screen Set up temperature control, flow rate, valve control, etc
 Dimensions/ Weight 350(W) x 220(H) x 500(D) mm / 14.3Kg  
 Power supply AC100V 50/60Hz 15A 
Flow controller 
 RF power unit 600kHz, 48W  
 Contents Split valve and built-in pressure controller
 Dimensions/ Weight 350(W) x 180(H) x 500(D) mm / 15.2Kg 
Liquid nitrogen dewar vessel and siphon
 Liquid nitrogen dewar   vessel Internal volume 50 liter Internal volume 20 liter 
 Dimensions/ Weight 460(OD) x 930(H) mm / 24.8Kg 390(OD) x 650(H) mm /  9.2Kg  
 Siphon  1000mm long, with solenoid valve 800mm long, with solenoid valve
Overheat prevention unit (Option) *2
 Temp. sensor 4 sensors
 Power supply 15A Sensitivity current 30mA  Emergency stop button is installed
 Dimensions/ Weight 350(W) x 170(H) x 500(D) mm / 8Kg 

  JTD-505Ⅲ JTD-505MⅢ
Device unit
PAT thermal desorption 0°C to 350°C (Cooling by LN2, Heating by resistance heating) *1
Transfer line Ambient plus 10°C to 350°C (Heating by resistance heating)
Metal capillary tube
SAT thermal desorption  Heting by curie point method
(standard 280°C)
SAT   Quartz glass packed with TenaxTA
and pyrofoil 280
SAT cooling unit  minus 100°C to ambient
(Cooling by LN2)
SAT oven unit  Ambient plus 10°C to 230°C
(Heating by resistance heating)
Needle  Ambient plus 10°C to 300°C
(Heating by resistance heating)
GC connection  Direct connection to
capillary column or injector
Dimensions, Weight  255(W) x 210(H) x 105(D) mm, 3 Kg  
Loader
PAT rack 15 tubes + 1 tube at home position
for position calibration and blank test
Carrying mechanism Motor drive
PAT induction air plunger Compressed air > 0.5 MPa
Dimensions, Weight 670(W) x 200(H) x 760(D) mm, 14.3 Kg  
Controller
Touch panel screen Set up temperature control, flow rate, valve control, etc
Dimensions, Weight 350(W)×220(H)×500(D)mm・14.3Kg    
Power AC100V 50/60Hz 15A
Flow controller
RF power unit 600kHz 48W  
Contents Split valve and built-in pressure controller
Dimensions, Weight 350(W) x 180(H) x 500(D) mm, 15.2 Kg 
Liquid Nitrogen Dewar Vessel and Siphon
Liquid Nitrogen Dewar Vessel Internal volume 50 liter  Internal volume 20 liter
Dimensions, Weight 460(OD) x 930(H) mm / 24.8 Kg 390(OD) x 650(H) mm / 9.2Kg
Siphon 1000 mm long with solenoid valve 800 mm long with solenoid valve
Overheat prevention unit (Option) *2
Temp. sensor      4 sensors
Power      15A Sensitivity current 30mA Emergency stop button is installed
Dimensions, Weight     350(W) x 170(H) x 500(D) mm, 8 Kg 

*1 For normal operation, it usually set at 60°C or higher. Between 0°C to 60°C is possible to set too, however, it cannot control the temperature precisely and it could fluctuate.  Sampling in a cooler environment than ambient is also not recommended, considering the wait time on the sample rack.
 
*2 In case of thermal runaway in the heating units, the optional overheat prevention unit can turn off the main power supply. JTD-505 III has maximum temperature control software installed as standard specification. This option is for additional prevention.