HOME | Products | Pyrolyzer | JHP-10

JHP-10

JHP-10

A pyrolyzer specially focused on pyrolysis

A pyrolyzer specially focused on pyrolysis

If all you want is to pyrolyze samples at desired temperature, JHP-10 will be an adequate model to meet your requirement.
 
Stable chromatograms
It uses pulse heating mechanism applied with induction heating and Curie Point of ferromagnetic properties named pyrofoils. Sample as a whole is heated efficiently in enfolded pyrofoil and provides reproducible sharp chromatograms. 
 
Intuitive operation
Method can be set from the touch panel screen on controller. JHP-10, however, does not have complicated programs. Operational setup can be done quickly and easily.
 
Easily removable modul
Sample tube holder is an assembly of sample tube and needle. All the flow channel is easily removable at once from the pyrolyzer. Remained Tar-like residues in sample tubes are one of the serious bottlenecks of pyrolysis, however, JHP-10 minimizes unwanted ghost peaks and cross contamination thanks to the easily cleanable and replaceable sample tube.
 
Easy to access GC inj. port
The pyrolyzer can be slid away easily to allow for micro syringe injection and GC maintenance. (Some GCs are not compatible. Ask for details.)
 
 

 
Sample tube holder
The pyrolyzer can slide backward.
 
 
 

If all you want is to pyrolyze samples at desired temperature, JHP-10 will be an adequate model to meet your requirement.
 
Stable Chromatograms
It uses pulse heating mechanism applied with induction heating and Curie Point of ferromagnetic properties named pyrofoils. Sample as a whole is heated efficiently in enfolded pyrofoil and provides reproducible sharp chromatograms. 
 
Intuitive Operation
Method and condition can be set from the touch panel screen on controller. JHP-10, however, does not have complicated programs or many features. Operational setup can be done quickly and easily.
 
Easily removable module
Sample tube holder is an assembly of sample tube and needle. All the flow channel is easily removable at once from the pyrolyzer. Remained Tar-like residues in sample tubes are one of the serious bottlenecks of pyrolysis, however, JHP-10 minimizes unwanted ghost peaks and cross contamination thanks to the easily cleanable and replaceable sample tube.
 
Easy to access GC inj. port
The pyrolyzer can be slid away easily to allow for micro syringe injection and GC maintenance. (Some GCs are not compatible. Ask for details.)
  

Sample tube holder
 
 
 
Pyrolyzer can slide backward.
 

Specification

Specification

Curie Point Pyrolyzer JHP-10
 Heating Method Curie Point Heating
 Pyrolysis Period 1 - 99 sec
 Pyrolysis Temp. By choosing a Pyrofoil temp.
range from 160°C - 1040°C
 RF Generator Radio frequency output: 48W
Fall detect sensor is installed
 Dimensions / Weight Pyrolyzer : W120 x D121 x H328 mm / 2 Kg
Controller : W180 x D500 x H390 mm / 16Kg
 Power 100-220V, 500VA Max.

 

Curie Point Pyrolyzer JHP-10
 Heating Method Curie Point heating
 Pyrolysis Period 1 - 99 sec
 Pyrolysis Temp. By choosing a Pyrofoil Temp.
range from 160°C - 1040°C
 RF Generator Radio frequency output: 48W
Fall detect sensor is installed
 Dimensions / Weight Pyrolyzer : W120 x D121 x 328H mm / 2 Kg
Controller : W180 x D500 x H390 mm / 16Kg
 Power 100-220V, 500VA Max.

Auto Pyrofoil Sampler for JHP-10

Auto Sampler for JHP-10

Pyrofoil Sampler APS-50

 
Automates the sample feeding/collection process for Pyrofoils.
 
Foil Magazine can set 50 Pyrofoils at a time
 

 Specification

Pyrofoil Sampler APS-50
 Number of Samples 50 Pyrofoils
 Sample Loading By Foil magazine
 Sample Retrieval By magnetic retriever stick
 Air Purge Auto purge by solenoid valve
 Dimensions (Including Pyrolyzer)
W275 x D272 x H612 mm / 6Kg

  
 
 
APS-50 mounted on Pyrolyzer JHP-10
 

Pyrofoil Sampler APS-50

 
Automates the sample feeding/collection process for Pyrofoils.
 
Foil Magazine can set 50 Pyrofoils at a time.
 

 Specification

Pyrofoil Sampler APS-50
 Number of samples 50 Pyrofoils
 Sample loading By Foil magazine
 Sample retrieval By magnetic retriever stick
 Air purge Auto purge by solenoid valve
 Dimensions (Including Pyrolyzer)
W275 x D272 x H612 mm / 6Kg

 
 
 
 
APS-50 mounted on JHP-10
 

Curie Point Pyrolyzer

 
 Hybrid Pyrolyzer
JHI-08 
 
 
 
Curie Point Pyrolyzer