Please select one of the following tabs of columns.
Other selective columns
Please select one of the following tabs of columns.
iCHIRAL Series
▮Immobilized Polysaccharide chiral columns (Made by Daicel)
This highly solvent-resistant column series was developed with a concept of "Chiral columns that can be used with broad range of organic solvents as eluents". You can use alkanes and alcohols in addition to all the solvents being used for HPLC such as Ethyl Acetate, THF and halogenated solvents. Further, Semi-prep columns (20mm ID) are "footless columns", meaning giving very sharp peaks with no tailing, which results in larger injection loadability and higher enantiomeric resolution.
※1: The flow rates are for reference only, Actual flow rate must be controlled so that the pressure does not exceed the limit specified in the Operation Manual. ※2: Three pieces per set. To use the cartridge, Cartridge Holder (Item #00011) is needed. ※3: Analytical columns must be used with analytical HPLC.
iCHIRAL Series
▮Immobilized Polysaccharide chiral columns (Made by Daicel)
This highly solvent-resistant column series was developed with a concept of "Chiral columns that can be used with broad range of organic solvents as eluents". You can use alkanes and alcohols in addition to all the solvents being used for HPLC such as Ethyl Acetate, THF and halogenated solvents. Further, Semi-prep columns (20mm ID) are "footless columns", meaning giving very sharp peaks with no tailing, which results in larger injection loadability and higher enantiomeric resolution.
※1: The flow rates are for reference only, Actual flow rate must be controlled so that the pressure does not exceed the limit specified in the Operation Manual. ※2: Three pieces per set. To use the cartridge, Cartridge Holder (Item #00011) is needed. ※3: Analytical columns must be used with analytical HPLC.
Buckyprep series is specially designed for fullerene separation. This is a most suitable column with its high performance as it takes 10 times larger quantity of sample at a time and complete separation within half of the time GPC columns generally take. For fullerene separation, Buckyprep column with our recycling preparative HPLC is the world benchmark of HPLC column.
Fullerene separation column from NACALAI TESQUE, INC. ▮ BUCKYPREP Series for Fullerene Buckyprep series is specially designed for fullerene separation.
This is a most suitable column with its high performance as it takes 10 times larger quantity of sample at a time and complete separation within half of the time GPC columns generally take. For fullerene separation, Buckyprep column with our recycling preparative HPLC is the world benchmark of HPLC column.